- NVCHARGE SOLUTION FOR ELECTRIC VEHICLES
- DANFOSS
- RENEWABLE ENERGY
- INTERGRATED SOLUTIONS
- Medium and low voltage inverter system
- Conveyor Weighing System
- Automatic transfer switch system - ATS
- Motor control center system - MCC
- Distributed Control System - DCS
- PLC - SCADA control system
- TPS control system
- Online coal analyzer and monitor system
- MV and LV soft start system
- UPS system
- MDB & DB distribution cabinets, power supply cabinets
- MARECHAL - TECHNOR
- BORRI
- FLENDER
- DURAG
- SOLCON
- SIEMENS
- METSO OUTOTEC
- TECHNICAL SERVICE
Product Categories
Liên hệ:
|
|
Hot line: 0902 195 055 |
|
VP Hà Nội : 024 6269 7755
VP HCM : 028 3517 8949
|
Liên hệ:
|
|
Hot line: 0902 298 455 |
|
VP Hà Nội : 024 6269 7755
VP HCM : 028 3517 8949
|
Supplier
SITRANS LR250
SITRANS LR250 is your first choice for liquid level measurement in storage and process vessels up to 20 meters (66 ft). With its range of antennas, this transmitter can handle whatever you need it to. Its new flanged and hygienic encapsulated antennas mean corrosive or aggressive materials and hygienic or sanitary requirements are no challenge for this transmitter.
SITRANS LR250 Horn antenna
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft).
SITRANS LR250 PVDF antenna
SITRANS LR250 with threaded PVDF antenna is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including corrosives or aggresive materials, to a range of 10 m (32.8 ft).
SITRANS LR250 Flanged encapsulated antenna
SITRANS LR250 with flanged encapsulated antenna is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including corrosives or aggressive materials, to a range of 20 m (66 ft) (antenna dependent).
SITRANS LR250 Hygienic Encapsulated Antenna
SITRANS LR250 hygienic encapsulated antenna is a 2 wire 25 GHz pulse radar level transmitter with sanitary and hygienic approvals for continuous monitoring of liquids, slurries and pastes within the Food, Beverage, chemical and pharmaceutical industries to a range of 20 m (66 ft) – antenna dependent.
Detail
SITRANS LR250 Horn antenna
Technology | Pulse radar |
Range | 20m (66 ft) |
Process Temperature | -40 to 200 °C (-40 to 392 °F) |
Process Pressure | Up to 40 bar g (580 psi g) |
Maximum measured error | 3 mm (0.118 inch) |
Certificates and approvals | General Purpose, Intrinsically Safe, Explosion Proof/Flame Proof, Non Sparking/Non Incendive, Increased Safety |
SITRANS LR250 PVDF antenna
Technology | Pulse radar |
Measurement range | 10m (32.8 ft) |
Process temperature | -40 to 80 °C (-40 to 176 °F) |
Pressure (vessel) | Up to 5 bar g (72.5 psi g) |
Maximum measured error | 3 mm (0.118 inch) |
Certificates and approvals | General Purpose, Intrinsically Safe, Explosion Proof/Flame Proof, Non Sparking/Non Incendive, Increased Safety |
SITRANS LR250 Flanged encapsulated antenna
Technology | Pulse radar |
Measurement range | 20m (66 ft) |
Process temperature | -40 to 170 °C (-40 to 338 °F) |
Pressure (vessel) | See Pressure/Temperature curves in the catalog for more information |
Maximum measured error | • > 500 mm from sensor reference point: 3 mm (0.118 inch) • < 500 mm from sensor reference point: 25 mm (1 inch) |
Certificates and approvals | General Purpose, Intrinsically Safe, Explosion Proof/Flame Proof, Non Sparking/Non Incendive, Increased Safety |
SITRANS LR250 Hygienic Encapsulated Antenna
Technology | Pulse radar |
Measurement range | 20m (66 ft) |
Process temperature | -40 to 170 °C (-40 to 338 °F) |
Pressure (vessel) | See Pressure/Temperature curves in the catalog for more information |
Maximum measured error | • > 500 mm from sensor reference point: 3 mm (0.118 inch) • < 500 mm from sensor reference point: 25 mm (1 inch) |
Certificates and approvals | 3-A, EHEDG EL Class I, EHEDG EL Aseptic Class I General Purpose, Intrinsically Safe, Explosion Proof/Flame Proof, Non Sparking/Non Incendive, Increased Safety |
Benefits
SITRANS LR250 Horn antenna
- Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard
- LUI displays echo profiles for diagnostic support
- 25 GHz high frequency allows for small horn antennas for easy mounting in nozzles
- Insensitive to mounting location and obstructions, and less sensitive to nozzle interference
- Short blanking distance for improved minimum measuring range to 50 mm (2″) from the end of the horn
- Communication using HART® or PROFIBUS PA, or FOUNDATION Fieldbus TM
- Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions
- Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM.
- Suitable for use in safety related systems in accordance with IEC 61508/61511 (SIL-2)
- 3mm (0.118 inch) accuracy in accordance with IEC 60770-1
SITRANS LR250 PVDF antenna
All the benefits of SITRANS LR250 Horn antenna and the following:
- Fully insulated Threaded PVDF antenna designed for use in simple applications within chemical environments where aggressive and corrosive materials are used
- Cost effective replacement for transmitters made of exotic materials
- 2″ (50 mm) threaded process connection/antenna allow for easy mounting in nozzles
SITRANS LR250 Flanged encapsulated antenna
All the benefits of SITRANS LR250 Horn antenna and the following:
- Fully encapsulated horn antenna design with flange mount and FDA approved flush faced TFM 1600 PTFE lens for use in chemical and sanitary environments where aggressive and corrosive materials are used
- Flush lens antenna allows for easy cleaning and less intrusion in vessel
- Cost effective replacement for transmitters made of exotic materials
- 2 inch (50 mm) process connection/antenna allow for easy mounting
SITRANS LR250 Hygienic Encapsulated Antenna
All the benefits of SITRANS LR250 Flanged Encapsulated antenna and the following:
- < 0.8 μ Ra surface finish for maximum cleanability and hygiene requirements commonly required in sanitary environments
- Industry standard process connections (DIN 11851, ISO 2852 (tri-clamp), DIN 11864, Tuchenhagen Varivent Types F and Type N
- 3-A, EHEDG EL Aseptic Class I, EHEDG EL Class I
- FDA and USP Class VI approved materials
Sản phẩm liên quan
SITRANS Probe LR
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in
SITRANS LR560
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range of
SITRANS LR460
The SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal
SITRANS LR260
SITRANS LR260 is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage
SITRANS LR250
SITRANS LR250 is your first choice for liquid level measurement in storage and process vessels up to 20 meters (66
SITRANS LR200
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
- NVCHARGE SOLUTION FOR ELECTRIC VEHICLES
- DANFOSS
- RENEWABLE ENERGY
- INTERGRATED SOLUTIONS
- Medium and low voltage inverter system
- Conveyor Weighing System
- Automatic transfer switch system - ATS
- Motor control center system - MCC
- Distributed Control System - DCS
- PLC - SCADA control system
- TPS control system
- Online coal analyzer and monitor system
- MV and LV soft start system
- UPS system
- MDB & DB distribution cabinets, power supply cabinets
- MARECHAL - TECHNOR
- BORRI
- FLENDER
- DURAG
- SOLCON
- SIEMENS
- METSO OUTOTEC
- TECHNICAL SERVICE
Product Categories
Liên hệ:
|
|
Hot line: 0902 195 055 |
|
VP Hà Nội : 024 6269 7755
VP HCM : 028 3517 8949
|
Liên hệ:
|
|
Hot line: 0902 298 455 |
|
VP Hà Nội : 024 6269 7755
VP HCM : 028 3517 8949
|