HRVS-DN TX

HRVS-TX Eliminating Transformer Inrush Current for low and medium voltage transformers

Solcon’s latest development in the field of Medium Voltage Inrush current limiting technology.

The HRVS-TX is the ideal soft-starting solution for medium and low voltage transformers. The sophisticated TSR-6 transformer protection and control relay ensures the elimination of the magnetizing inrush current, thus, eliminates nuisance tripping as well as dynamic shock to the transformer windings. The starter can be supplied as IP31-67, NEMA 1-6X with options such as Line and Bypass vacuum contactors or circuit breakers, disconnect switches, main and control protection fuses, transformer protection relay, etc.

HRVS-TX Advantages at a glance

  • TSR-6 Control and protection relay-the only relay of its kind
  • Heavy duty design at 50°C ambient temperature
  • Reduced inrush current and dynamic shock
  • Applicable models for any transformer
  • Optional protection package provides many features
  • Single and Multi transformer soft-starting
  • Transformer heat protection relay – optional
  • Communication – RS485 Modbus or Profibus
  • Unique starting characteristics
  • User friendly, easy setup and operation
  • IP31-standard, higher protection by special order
  • Phase shift transformer starting, unique technology
  • Innovative low voltage test modes
  • Advanced “wireless” Electronic Potential Transformer (optional)
  • Fault indication to each individual fuse
  • Each transformer starter is tested for Partial Discharge (Korona)
  • Wide 40-70Hz range for fluctuating frequency systems
  • Available as stand alone or Integratable with Solcon’s
  • HRVS-DN medium and low voltage soft starters

Starting 6.5MVA Transformer Direct On line

Current in Amperes vs. Time in Seconds

4900A, for 2.5 seconds

Soft-Starting 6.5MVA Transformer

Current in Amperes vs. Time in Seconds

65A, for 0.2 seconds

The complete Set of the Medium Voltage Transformer Soft Starter

integrated with the TSR-6 into a second generation “All in one” unit.

Basic Block Diagram

Khởi động mềm trung áp

Sản phẩm liên quan

HRVS-DN TX

HRVS-TX Soft-Starter for Medium Voltage Transformer: Up to 30MW, 15kV

HRVS-DN

HRVS-DN Medium Voltage soft starter for Motors 30-3000A, 1500-15000V, 30KW - 50000KW

Medium Voltage Soft Starter Integrated Motor Insulation Protection

HRVS DN MEGA

Download Up to 75MW – HRVS-DN MEGA Starter HRVS DN MEGA Medium Voltage Soft Starters for 12MW, 15MW, 17MW, 20MW, 24MW,

HRVS – DN EX

50-2700A, 1500-15000V

HRVS-DN-EX 50-2700A, 1500-15000V

© Copyright 2003-2022 - Công ty CP TMKT Hải Anh - Hai Anh JSC, Địa chỉ: P301, Nhà D5C, đường Trần Thái Tông, Q.Cầu Giấy, TP. Hà Nội, Việt Nam | ĐT: (+84-24) 6269 7755 | Fax: (+84-24) 6269 5556

Chạm để gọi